蒽醌法过氧化氢装置污水处理优化研究
Optimization study on sewage treatment of hydrogen peroxide plant by anthraquinone process
成小强 1李帅超 1冯彬 1白立光 1王创业 1曹国平1
作者信息
- 1. 黎明化工研究设计院有限责任公司,河南洛阳 471000
- 折叠
摘要
针对过氧化氢装置污水处理系统运行过程中出现的污水分析数据不达标、指标波动大、絮凝沉淀分层效果不佳等现象,从氧化残液量大、隔油池内有机物多、Fenton氧化池投加药剂比例不合适等几方面进行了分析,并提出优化措施,保证污水处理系统的正常运行.对目前国内蒽醌法制过氧化氢污水处理工艺的改进情况进行了总结.
Abstract
In view of the phenomenon including substandard sewage analysis data,great fluctuation of indexes,and poor flocculation and precipitation stratification effect,etc.occurred during the operation of the sewage treatment system of hydrogen peroxide plant,the analysis was performed from several aspects such as large amount of oxidized residual liquid,large amount of organic substances in the oil separation tank,and inappropriate ratio of chemical reagents added to Fenton oxidation tank,etc.,and the optimization measures were proposed to ensure the normal operation of the sewage treatment system.The improvements to the current domestic sewage treatment process for preparing hydrogen peroxide by anthraquinone process were summarized.
关键词
蒽醌法/Fenton氧化-絮凝法/污水处理/再生污水/氧化残液Key words
anthraquinone process/Fenton oxidation-flocculation method/sewage treatment/reclaimed sewage/oxidized residual liquid引用本文复制引用
出版年
2024