首页|水电站变压器绝缘老化故障原因与对策分析

水电站变压器绝缘老化故障原因与对策分析

扫码查看
阐述案例故障的调查与实验,分析长期运行导致绝缘材料老化、环境湿度过高以及操作不当或过载使用造成过热原因.提出定期检测和维护绝缘材料、控制环境湿度、合理规划变压器负载的措施.
Analysis of Causes and Countermeasures of Insulation Aging Faults in Hydropower Station Transformers
This paper describes the investigation and experimentation of case failures,analyzing the reasons for insulation material aging,high environmental humidity,and overheating caused by improper operation or overloading during long-term operation.It proposes measures for regular testing and maintenance of insulation materials,control of environmental humidity,and rational planning of transformer loads.

transformerinsulation agingcause of failure

杨万翠

展开 >

甘肃电投大容电力有限责任公司,甘肃 730030

变压器 绝缘老化 故障原因

2024

集成电路应用
上海贝岭股份有限公司

集成电路应用

影响因子:0.132
ISSN:1674-2583
年,卷(期):2024.41(3)
  • 5