Design of a Perforation Section Casing Damage Monitoring System
This paper expounds the overall structure of the underground detection system,analyzes the excitation mode of the transmission module,and designs the excitation circuit.It explores the influence of transmission coil parameters on turn off time,optimization of secondary field reception module,and implementation of secondary field reception using GMR sensor array.