采用Herriott型长光程池结构原理,通过理论研究和仿真分析得到一定条件下Herriott池反射次数最优解,利用镀膜凹面镜作为反射镜,在池体上集成光学元件,进行了长光程、低成本、小体积光程池的设计.经过实验验证,所设计的物理长23 cm,体积243 mL的光程池,能达到11 m有效光程长,并搭建在TDLAS甲烷检测系统中,结果表明检测下限最低浓度为47.6 ppb.这为低浓度、高精度、微型化的TDLAS甲烷检测系统的推广应用提供了一种有效的途径.
Research and design of long optical range cell based on TDLAS methane detection system
In this paper,the structural principle of Herriott-type long optical range cell is adopted,and the optimal so-lution for the number of reflections of the Herriott cell under certain conditions is obtained through theoretical research and simulation analysis,and the design of a long optical range,low-cost and small-volume optical range cell is carried out by utilizing coated concave mirrors as mirrors,and by integrating the optical elements in the cell body.After exper-imental verification,the designed light-range cell with a physical length of 23 cm and volume of 243 mL of optical range cell can achieve 11 m effective optical range length,and built in the TDLAS methane detection system.The re-sults show that the lower limit of detection is the lowest concentration of 47.6 ppb,which provides an effective way promote the application of the low-concentration,high-precision,and miniaturized TDLAS methane detection system.