首页|冷屏对红外焦平面探测器组件性能的影响

冷屏对红外焦平面探测器组件性能的影响

扫码查看
分析了国内早期中波320 ×256红外焦平面探测器组件与国外同类产品在装机性能上的差异,采用三种实验方法检测了国内外探测器组件的光电性能,通过对探测器组件光电转换和结构的分析,确定出杂散光在冷屏内部的反射是导致测试结果差异的原因,冷屏内表面黑化层和结构形式是影响组件实际应用的关键.冷屏结构改进后,有效改善了国内探测器组件的实际应用性能.
The impact of cold screens on the performance of infrared focal plane detector component
In this paper,the differences in installed performance between early domestic medium-wave 320 ×256 in-frared focal plane detector components and their foreign counterparts are analyzed.Three experimental methods are employed to test the photoelectric performance of detector components at home and abroad.By analyzing the photoelec-tric conversion and structure of the detector components,it is determined that the reflection of stray light inside the cold screen is the reason for the difference in the test results,and the blackened layer on the inner surface of the cold screen and the form of its structure are key to the practical application of the component.The improved structure of the cold screen effectively improves the practical application performance of domestic detector modules.

cold screenradiationinfrared focal plane detectorstray light

甘玉梅、赵农、于小兵

展开 >

中国电子科技集团公司第十一研究所,北京 100015

冷屏 辐射 红外焦平面探测器 杂散光

2024

激光与红外
华北光电技术研究所

激光与红外

CSTPCD北大核心
影响因子:0.723
ISSN:1001-5078
年,卷(期):2024.54(6)