首页|对光柱式血压计校准方法的初步探讨与分析

对光柱式血压计校准方法的初步探讨与分析

扫码查看
光柱式血压计是采用光柱替代水银作为血压计的指示器,具有清晰直观、使用方便、抗震、抗冲击和可靠耐用等特点,但目前尚未有相关的国家检定规程或校准规范.本文根据该血压计的相关特性,对校准方法进行探讨,并对试验数据进行分析.实验证明:该校准方法对其外观、零位误差、压力示值误差、气密性的校准具有可操作性,可在无检定规程或校准规范的情况下,为量值溯源提供依据.
A Preliminary Discussion and Analysis on the Calibration Method of Light Column Sphygmomanometer
Light column sphygmomanometer is the use of light column instead of mercury as a sphygmomanometer indicator,with clear and intuitive,easy to use,seismic,shock resistance and reliable and durable characteristics,but there is no relevant national verification regulations or calibration specifications.According to the related charac-teristics of the sphygmomanometer,the calibration method is discussed and the test data is analyzed.Experimental results show that this method is feasible to calibrate the appearance,zero error,pressure indication error and air tightness,and can provide a basis for quantity traceability without verification rules or calibration specifications.

sphygmomanometerlight column sphygmomanometercalibration method

李赟、强学栋、骆翠霞

展开 >

南通市计量检定测试所

血压计 光柱式血压计 校准方法

2024

计量与测试技术
成都市计量监督检定测试所

计量与测试技术

影响因子:0.175
ISSN:1004-6941
年,卷(期):2024.51(2)
  • 6