首页|利用液体密度标准物质校准振动式密度仪

利用液体密度标准物质校准振动式密度仪

扫码查看
针对JJG 1058-2010《实验室振动式液体密度仪》,提出采用液体密度标物(密度标物)校准振动式液体密度仪(密度仪)的方法,并与上海市计量院(SIMT)进行精密级密度仪比对试验.在(650~2000)kg/m3范围内,选取3种物理和化学性质稳定的密度标物作为计量标物,对密度仪进行校准,并分析密度标物的计量特性.结果表明:|En|最大为0.3,比对结果满意,可为该类仪器的校准提供一种现实可行的方法,有助于我国高精度密度测量仪器的研制和开发.
Calibration of Vibrating Density Meter Using Liquid Density Reference Material
According to JJG 1058-2010"Laboratory Oscillation-type Liquid Density Meters",a method of cali-brating vibratory liquid densitometer(densitometer)with liquid density standard(densitometer)was proposed,and the precision level densitometer was compared with SHANGHAI Institute of Metrology(SIMT).In the range of(650~2000)kg/m?,three density markers with stable physical and chemical properties were selected as measure-ment markers,the density meter was calibrated,and the measurement characteristics of the density markers were an-alyzed.The results show that the maximum value of | En | is 0.3,and the comparison results are satisfactory,which provides a practical and feasible method for the calibration of such instruments,and is helpful to the research and development of high-precision density measuring instruments in our country.

density standard materialu-shaped vibrating tubedensity measurementcomparative test

张怡雯、陈超云、雷鸣、许诚

展开 >

苏州市计量测试院

上海市计量测试技术研究院

苏州城市学院

密度标准物质 U型振动管 密度测量 比对试验

2023年教育部产学合作协同育人项目2023年江苏省大学生创新创业训练计划2022年教育部高等学校科学研究发展中心中国高校产学研创新基金项目

230805377071846202313983048Y2022BL082

2024

计量与测试技术
成都市计量监督检定测试所

计量与测试技术

影响因子:0.175
ISSN:1004-6941
年,卷(期):2024.51(3)
  • 11