采用不同类型的气体流量计作为粉尘采样器校准装置的标准流量装置,对指示式和数显式粉尘采样器分别进行流量校准,并将管路负压、环境温度与大气压对测量结果的影响进行分析.结果表明:皮膜流量计和孔口流量计的准确度较好、负载压力小,可作为该装置的标准流量计;指示式粉尘采样器测量结果需根据管路负压、环境温度及大气压的影响.
Abstract
Different types of gas flowmeters are used as the standard flow devices of dust sampler calibration equip-ment,and the flow calibration of indicating and digital dust sampler is carried out respectively.The influence of pipeline negative pressure,ambient temperature and atmospheric pressure on the measurement results is ana-lyzed.The results show that the membrane flowmeter and the orifice flowmeter have better accuracy and less load pressure,and can be used as the standard flowmeter of the device.The measurement results of the indicating dust sampler must be based on the influence of pipe negative pressure,ambient temperature,and atmospheric pressure.
关键词
气体流量计/校准装置/粉尘采样器/负载压力Key words
gas flowmeter/calibration device/dust sampler/load pressure引用本文复制引用