Discussion on Measuring a Electronic Calibration Kit with Two Female-ports or Ith Two Male-ports Calibration Method by De-embedding
This paper introduces the de-embedding method,using vector network analyzer to measure special in-terfaces,such as double negative or double positive interface electronic calibration parts,to avoid complex data processing.At the same time,the influence of the fixture on the measured calibration part is eliminated,so that the measurement reference plane is transformed from the calibration network analyzer to the measurement result,so as to obtain the S-parameter values of the special interface electronic calibration part,and verify whether the parame-ters meet the requirements.
method by de-embeddingverification kitelectronic calibration kit with two female portselectronic calibration kit with two male portsmeasurement uncertainty