Optimization of sodium hypochlorite purification process
In view of such problems in acetylene sodium hypochlorite purification system as easy cor-rosion of equipment and pipeline and serious scaling in water washing tower and cooling tower,the process transformation was carried out.The positions of the water ring compressor and the acetylene gas holder in the process flow were changed,and the working medium of the water washing tower and the cooling tower was altered.After transformation,the corrosion and scaling problems were resolved.
acetylenesodium hypochloritepurification towerwater washing towerwater ring compressorgas holdercorrosion