首页|基于气象因素与卫星火点的配电网山火故障研究

基于气象因素与卫星火点的配电网山火故障研究

扫码查看
云南电网山区配网线路长,架空裸导线数量占比多,极易引发山火导致线路设备受损,为防范山火导致的配电线路故障,基于2023年3月至5月云南电网山火高发期内的气象数据与卫星监测的火点数据,对山火引起的配网线路故障进行分析.山火高发期内,检测到配网线路附近火点共634处,其中仅66起导致线路停运,大多数为配合消防停电,仅有一例为因山火导致的线路故障停运.另检测到32起由线路故障导致的火源,其中占比最高的为树木搭接至线路上导致的故障.统计结果表明,目前卫星监测到的火点冗余信息较多,以树障为主的线路故障信息反馈不及时,未来仍应继续完善配网灾害系统.
Study of Hill Fire Faults on Distribution Network Based on Meteorological Factors and Satellite Fire Points
Yunnan Power Grid has long distribution lines in mountainous areas,and the number of overhead bare conductors accounts for a large proportion,which is very easy to cause damage to line equipment caused by mountain fires,in order to prevent distribution line failures caused by mountain fires.This paper analyzes the distribution grid faults caused by wildfires based on the meteorological da-ta and satellite monitoring fire point data during the high incidence period of wildfires in Yunnan Power Grid from March to May 2023.Since the average precipitation and temperature from March to May this year were lower than the same period of previous years,the number of wildfires observed this year in-creased significantly,of which a total of 66 faults were detected due to line outages caused by wildfires,most of which were in cooperation with fire and power outages,and only one case was a line failure caused by wildfires.In addition,32 ignition sources caused by line faults were detected,of which the highest proportion was caused by trees lapping onto the line.For the above two types of wildfire faults,typical cases of faults are listed and analyzed.According to the analysis results,the problems existing in the current fire prevention work of the distribution network are pointed out.

forest firetransmission linedistributional characteristics

沈宗云、谭一元、李海龙、王科、沈雪明、何建波、宁文军

展开 >

云南电网有限责任公司丽江供电局,云南丽江 674100

云南电网有限责任公司,云南 昆明 650000

云南电网有限责任公司电力科学研究院,云南 昆明 650217

四川大学电气工程学院,四川成都 610065

展开 >

山火 输电线路 分布特性

2024

佳木斯大学学报(自然科学版)
佳木斯大学

佳木斯大学学报(自然科学版)

影响因子:0.159
ISSN:1008-1402
年,卷(期):2024.42(11)