针对高压交流输电线路短路故障情况,将三相交流电流和电压信号进行小波包变换以提取故障特征,然后将提取到的特征输入XGBoost模型中进行故障诊断.结果表明,与传统故障检测方法相比,基于小波包变换和XGBoost的故障诊断方法不受故障类型影响,对10种高压交流输电线路故障的识别准确率高达99.6%,是一种准确、可靠的高压交流输电线路故障诊断方法.
Fault Diagnosis of High-Voltage AC Transmission Lines Based on Wavelet Packet Transform and XGBoost
In view of the short-circuit fault situation of high-voltage AC transmission line,the three-phase AC voltage and current signals are transformed into wavelet packets to extract the fault features,and then the extracted features are input into the XGBoost model for fault diagnosis.The experimental re-sults show that the fault identification accuracy of the fault diagnosis method based on wavelet packet transform and XGBoost is 99.6%for the fault of high-voltage AC transmission line under different oper-ating conditions.Compared with other machine learning models,this method has high accuracy.