Finite element analysis and strength check of converter connection system
Taking the 230 t converter connection system as the research object,the ultimate working condition of the converter connection system is obtained by calculating the load change during the tilting process of the converter,and the stress distribution of the converter connection system and the maximum stress of the key parts under the ultimate working condition are obtained by Abaqus software,then the service strength of the converter connection system is checked.The results show that the connection system of converter can meet the service strength under the different ultimate working conditions.
converter connection systemultimate working conditionAbaqusstrength checkstressfinite element