首页|双膜法中水厂反渗透系统运行分析

双膜法中水厂反渗透系统运行分析

扫码查看
根据中水源双膜工艺水厂反渗透 4 年工程运行经验,分析了膜性能变化及维持膜高效的工程措施。结果表明,中水源双膜工艺反渗透稳定运行4 年,膜性能保持良好,标准化脱盐率均值为97。9%,较初始降低0。8%,平均年下降0。2%;98%保证率时,系统脱盐率从初始的 98。4%降至 97。4%,平均每年降幅为 0。25%;系统标准化膜通量保持率为 63。0%,进水压力稳定在 1。19 MPa,一段压差相比初始值仅增大 62。5%,与运行第一年水平相当,预测膜平均寿命能够达到 7 年;通过优化自控程序、严格控制进水氧化还原电位(ORP)及总氯、交替采用冲击式杀菌和清洗水箱杀菌、保持在线维护性清洗等综合手段,有效维持了膜性能,减缓膜性能衰减,延长膜寿命;工程电耗核算及预测表明,更换膜费用大大超过膜寿命延长增加的电费,应尽可能长维持膜寿命,延缓换膜时间,获得最大的经济效果;工程运行实践表明,国产阻垢剂、非氧化杀菌剂能够达到进口药剂相同效果,降低运行费用。
Summary of Experience in Reverse Osmosis Operation of Sewage Source UF-RO Process WTPs
Based on the four-year engineering operation experience of reverse osmosis(RO)in the reclaimed water source double-membrane process water treatment plant(WTP),the changes in membrane performance and engineering measures to maintain membrane efficiency were analyzed.The results showed that the RO system had been operating stably for four years,and the membrane performance had been maintained.The average value of the standardized desalination rate was 97.9%,which was 0.8%lower than the initial value,and the average annual decrease was 0.2%.Under 98%guarantee rate,the desalination rate dropped from the initial 98.4%to 97.4%,with an average annual decrease of 0.25%.The standardized membrane flux retention rate of the system was 63.0%,the inlet water pressure was stable at 1.19 MPa,and the first-stage pressure difference was only increased by 62.5%compared to the initial value,which was equivalent to the level of the first year of operation.It was predicted that the average life of the membrane could reach 7 years.By optimizing the automatic control program,strictly controlling the influent ORP and total chlorine,alternately adopting impact sterilization and cleaning water tank sterilization,maintaining online maintenance cleaning and other comprehensive methods,the membrane performance was effectively maintained and the degradation of membrane performance was slowed down.The membrane life was extended.Actual project electricity consumption calculations and forecasts showed that the cost of membrane replacement greatly exceeded the increased electricity costs of membrane life extension.The membrane life should be maintained as long as possible,and the membrane replacement time should be delayed to obtain the greatest economic effect.Engineering operation practice showed that domestic scale inhibitors,non-oxidizing fungicides could achieve the same effect as imported chemicals and reduce operating costs.

reverse osmosis(RO)reverse osmosis membranedesalination ratemembrane lifescale inhibitor non-oxidizing fungicidesonline maintenance cleaning

王金龙

展开 >

青岛锦龙弘业环保有限公司,山东青岛 266555

反渗透(RO) 反渗透膜 脱盐率 膜寿命 阻垢剂 非氧化杀菌剂 在线维护性清洗

青岛西海岸新区科技专项

2020-25

2024

净水技术
上海市净水技术学会,上海市城乡建设和交通委员会科学技术委员会办公室

净水技术

CSTPCD
影响因子:0.643
ISSN:1009-0177
年,卷(期):2024.43(1)
  • 5