首页|武汉市某污水处理厂地下式扩建设计案例

武汉市某污水处理厂地下式扩建设计案例

扫码查看
武汉市S污水处理厂已建规模为35万m3/d,规划规模为60万m3/d,扩建规模为10万m3/d,出水标准高于《城镇污水处理厂污染物排放标准》(GB 18918-2002)一级A标准。厂内有多套处理工艺、多处进水入口和排放出口,改造难度较大。经论证,扩建工程选用地下式构筑物,最大限度节约现有用地,并为远期扩建预留条件。工艺流程采用"多级预处理+改良AAO生化池+膜生物反应器(MBR)池+次氯酸钠接触消毒",运行至今出水稳定达标。S污水处理厂是武汉市唯一一座兼有地上式及地下式处理构筑物的污水厂,文章总结了污水厂地下式扩建的设计思路、设计参数和设计经验,作为同类污水厂改造的参考。
Engineering Design Case of WWTP Underground Extension in Wuhan City
S wastewater treatment plant(WWTP)in Wuhan City with capacity of 350 000 m2/d,whose planning capacity is 600 000 m3/d,is designed to be expended on a scale of 100 000 m3/d.The effluent standard is higher than the first class A criteria specified in Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant(GB 18918-2002).Due to several sets of treatment process,several raw water intakes and discharge outlets in the WWTP,modification has been complicated.After comparison,underground structure is selected in expansion project,in order to save the existing land to the maximum extent and reserve conditions for long-term expansion.The process adopts"multi-stage pre-treatment+modified AAO+MBR+disinfection by sodium hypochlorite",and the effluent quality meets the standard steadily.S WWTP is the only WWTP with both above-ground and underground treatment structures in Wuhan City.This paper has summarized the design ideas,design parameters and design experience of the underground extension of the WWTP,to provide a reference for the modification of similar WWTPs.

underground wastewater treatment plant(WWTP)modification and extensionprocess designmembrane bio-reactor(MBR)

杨墨、史航标、程瑞丰、刘佳、陈智

展开 >

中国市政工程中南设计研究总院有限公司,湖北武汉 430010

中建三局绿色产业投资有限公司,湖北武汉 430056

武汉市城市排水发展有限公司,湖北武汉 430070

武汉三镇实业控股股份有限公司,湖北武汉 430077

展开 >

地下式污水处理厂 改扩建 工艺设计 膜生物反应器(MBR)

2024

净水技术
上海市净水技术学会,上海市城乡建设和交通委员会科学技术委员会办公室

净水技术

CSTPCD
影响因子:0.643
ISSN:1009-0177
年,卷(期):2024.43(z1)
  • 6