Simulation Study on Thermal Environment of Transition Space at Commercial Complex Entrance
This article selects the common type of three-sided elevated entrance transition space in humid and hot regions,and uses ENVI-met soft-ware to simulate the thermal environment of entrance transition spaces with different elevated rates.The simulation time is selected in the summer when thermal comfort needs to be improved urgently,and the typical meteorological days that best represent the general climate characteristics of the entire summer are selected as the calculation days.Simulations show the impacts of different elevated rates and changes in elevated height on the thermal environment under the three-sided elevated modes.Finally,design suggestions are proposed for the transition space of the elevated entrance of the commercial complex.