给水排水2024,Vol.50Issue(8) :102-108.DOI:10.13789/j.cnki.wwe1964.2023.10.18.0001

不同偏置方式对专用通气排水系统排水特性的影响

Study on water capacity of building drainage system under long distance pipe offset

李建俊 黎洁 官钰希 张斌 尹浩然
给水排水2024,Vol.50Issue(8) :102-108.DOI:10.13789/j.cnki.wwe1964.2023.10.18.0001

不同偏置方式对专用通气排水系统排水特性的影响

Study on water capacity of building drainage system under long distance pipe offset

李建俊 1黎洁 1官钰希 2张斌 3尹浩然4
扫码查看

作者信息

  • 1. 广东省建筑设计研究院集团股份有限公司,广州 510010
  • 2. 深圳市水务(集团)有限公司,深圳 518031
  • 3. 中国电建集团成都勘测设计研究院,成都 610000
  • 4. 武汉大学土木建筑工程学院,武汉 430072
  • 折叠

摘要

排水管道偏置常常应用于商住两用的高层建筑中,但是这类设计会造成排水流态变化,导致管道内出现巨大压力波动,破坏卫生器具水封,污染室内环境.针对偏置距离为1.0 m、1.5 m两个场景开展了试验.试验在60 m高全尺寸实验塔中展开,采用定流量法,通过压力极限值和水封损失值来比较不同偏置距离下系统的最大通水能力.结果表明,这两个偏置距离对建筑排水系统的通水能力均有极大负面影响,通水能力降低50%以上,偏置距离1.5 m较1.0 m的负面影响更大.

Abstract

Drainage pipe offset is often used in high-rise buildings for both commercial and resi-dential purposes,but this kind of design will cause changes in drainage flow pattern,resulting in fierce pressure fluctuations in the pipe system,damaging the water seal of sanitary appliances and polluting the indoor environment.Existing studies have discussed the characteristics of short-dis-tance offset,and this paper carries out tests for scenarios with offset distances 1.0 m and 1.5 m.The test was carried out in a 60 m high full-size experimental tower.The constant flow method was used to compare the maximum water discharge capacity of the building drainage system at dif-ferent offset distances by comparing pressure limit values and water seal loss values.The results show that this two long-distance offset groups have great negative effects on the water flow capaci-ty of the building drainage system(decreasing more than 50%),and the longer the offset distance,the greater the negative effect.

关键词

建筑排水系统/长距离偏置/压力波动/水封损失

Key words

Building drainage system/Long distance pipe offset/Variation of pressure/Loss of water seal

引用本文复制引用

出版年

2024
给水排水
亚太建设科技信息研究院,中国建筑设计研究院,中国土木工程学会

给水排水

CSTPCD北大核心
影响因子:0.8
ISSN:1002-8471
段落导航相关论文