Design case of large-scale sewage treatment plant upgrading and expansion in an industrial park in Zhejiang province
The sewage treatment plant in an industrial park of Zhejiang province expand to a to-tal capacity of 500 000 m3/d,including a 300 000 m3/d upgrade project and a 200 000 m3/d expan-sion project.The project's inlet water is mainly composed of industrial wastewater from printing and dyeing and chemical industries,accounting for about 80%of the total inlet water volume.The inlet water contains many refractory and soluble organic substances with poor biodegradability.The effluent quality needs to meet the Class A standard of the Discharge standard of pollutants for municipal wastewater treatment plant(GB 18918-2002),which is extremely difficult to achieve.To ensure the stability and compliance of the effluent quality,the project has carefully de-termined the main treatment process for the sewage through pilot tests based on current operational experience:The upgrade project adopts biochemical system transformation-Fenton catalytic oxi-dation-Filtration;the expansion project adopts inlet water regulation-Coagulative precipitation-Enhanced biochemical treatment-Fenton catalytic oxidation-Filtration.Since the project was put into operation,the effluent has been stable and up to standard.
Industrial wastewaterAdvanced oxidation processesFenton catalytic oxidationPrinting and dyeing industryChemical industry