1 000MW发电机转子振动大原因分析与处理措施
Analysis of the Causes of Rotor Vibration of 1 000 MW Generator and Treatment Measures
周志凯1
作者信息
- 1. 广东电力开发有限公司,广东 广州 510000
- 折叠
摘要
针对某电厂1 000 MW发电机组转子振动大的现象,从该型号转子结构的特点出发,发现转子振动呈增大的趋势,着重描述了抽出转子和返厂检修发现的不正常情况,并进一步分析原因,提出处理措施,处理后转子运行良好,振动情况满足规程要求.
Abstract
In view of the phenomenon of large rotor vibration of 1 000 MW generator set in a power plant,starting from the characteristics of the rotor structure of this model,it is found that the rotor vibration is increasing,and the abnormal situation found in the extraction of the rotor and the return to the factory for maintenance is emphatically described,and the causes are further analyzed,and the treatment measures are proposed,and the rotor runs well after treatment,and the vibration meets the requirements of the regulations.
关键词
发电机转子/振动增大/阻尼条风孔错位/阻尼条拱翘变形Key words
Generator Rotor/Increased Vibration/the Damping Strip Air Hole is Misaligned/the Arch of the Damping Bar is Warped and Deformed引用本文复制引用
出版年