Analysis and Optimal Design of Disc-Type Progressive Cavity Pump Test Device
Through the analysis of the reasons for the low efficiency of the end disc type screw pump in the product test,put forward the optimization scheme for the end disc type screw pump product test device,the end disc type screw pump inlet and outlet direction combination is fixed,in the test to fix the direction of the inlet of the end disc type screw pump,by the end of the end disc type screw pump outlet location to set up rotary joints and plane support and other related parts,so that the test device can meet the requirements of the end disc type screw pump multiple inlet and outlet direction combination of test.By setting rotary joints and plane support and other related parts at the outlet position of the end-disc screw pump,the test device can meet the test requirements of multiple inlet and outlet directions of the end-disc screw pump.Through the optimisation scheme,the testing process of end-disc type screw pump can be simplified,which can solve the problems of low testing efficiency and cumbersome testing and adjustment process in the product testing of end-disc type screw pump,and achieve the testing work of different specifications of end-disc type screw pumps in various combinations of inlet and outlet directions can be quickly met by a set of testing device,which improves the testing efficiency,saves the cost of testing and better meets the high efficiency output of end-disc type screw pumps.The high efficiency output of the end-disc type screw pumps.
end-plate screw pumpefficiencytest devicerotary jointplane support