Analysis of the Reinforcement Treatment Technology of Brick-wood Mixed Structure House
Taking a brick-and-wood structure building as an example,through on-the-spot investigation and examination,PKPM software calculation and checking of anti-seismic measures,it is concluded that the bearing capacity and anti-seismic measures of the building do not meet the requirements,the strengthening measures are proposed from the aspects of foundation,load-bearing wall,timber floor and roof truss,newly-added concrete structural columns and ring beams,cracked wall and drainage of newly-added roof layer,the Structure System of the building is transformed from brick-wood mixed structure to masonry structure to ensure the safety and reliability of the building.
Brick and wood constructionTestingReinforcement treatment