Construction Monitoring and Analysis of the Axial Force of the Circle Beam of the Foundation Pit
A certain project has set up 6 monitoring points around the excavation area of a semi underground storage tank to monitor the axial force of the ring beam.The monitoring data was sorted and analyzed in the article.Based on the monitoring data,the monitoring results of the axial force of the ring beam were analyzed.The results showed that under the protection of the ring beam steel reinforcement,the drilling bite grouting pile was in a safe state.The ring bite grouting pile foundation pit support structure designed for semi underground storage tanks was reasonable and feasible,and the control effect on the deformation of the foundation pit was significant.
Foundation pitAxial force of the circle beamConstruction Monitoring