首页|既有建筑主体结构检测鉴定与加固分析

既有建筑主体结构检测鉴定与加固分析

扫码查看
文中介绍了一则火灾损坏建筑主体结构的修复实例,根据现场勘察和测试的结果,制定了该结构的加固方案.通过对建筑主体结构受损情况进行目测,然后进行分析和现场材料试验,以确定剩余结构的碳化深度;对受损混凝土和钢筋的规格进行抽样,测试其剩余强度;通过有限元分析构件的剩余结构能力.综合考虑结构现状和施工顺序,提出了两种修复方法.
Inspection,Appraisal and Reinforcement Analysis of the Main Structure of Existing Buildings
This paper introduces an example of repairing the main structure of a building damaged by fire,describes the results of on-site in-vestigation and test,and formulates the reinforcement scheme of the structure.Through the visual observation of the damage of the main struc-ture of the building,and then the analysis and field material test are carried out to determine the carbonization depth of the remaining structure,sample the specifications of damaged concrete and steel bar,and test their residual strength.and the residual structural capacity of the mem-bers is analyzed by finite element method.Considering the present situation of the structure and the construction sequence,two repair methods are put forward.

Building main bodyReinforcementResidual strength

丰圣钦

展开 >

广东惠众建筑工程检测鉴定有限公司,广东 广州 510515

建筑主体 加固 剩余强度

2024

江西建材
江西省建材科研设计院

江西建材

影响因子:2.247
ISSN:1006-2890
年,卷(期):2024.(8)