城市轨道交通地下车站一般位于埋深4~40m的地下含水层中,为解决地下车站水淹及漏水问题,防止产生薄弱点,文中从排水组织、设备安装的角度,分析研究了地下车站防排水系统各项优化措施,明显改善了防排水薄弱点,应用效果良好,可为今后的类似项目设计提供参考.
Research on the Optimization Design of Anti-drainage in Underground Stations of Urban Rail Transit
Urban rail transit underground stations are generally located in underground water-content layers with 4-40m deep depth.In order to solve the problem of flooding and leakage of underground stations,and preventing weaknesses,this article analyzes the underground station from the perspective of drainage tissue and equipment installation.The optimization measures of the water-proof water-proof system have sig-nificantly improved the weakness of the water-proof and drainage,and the application effect is good.It is worthy of reference in the future simi-lar project design.