Research on Construction Technology of Reinforced Truss Concrete Composite Floor Slab
Taking a high-rise office building in Fujian Province as an example,the load bearing capacity,crack resistance and durability of the building were evaluated by finite element simulation and field test.The results show that the maximum deflection of reinforced truss concrete composite floor slab under the maximum design load of 10.5kN/mw is 4.2mm,which is far less than the standard limit of 24mm.In practical engineering application,the technology shortens the construction period by 20%,saves the template consumption by 50%,and reduces the to-tal construction cost by about 15%.Reinforced truss concrete composite floor slab has a wide application prospect in high-rise buildings,in-dustrial plants and public buildings.