扫码查看
按照国家碳中和发展战略规划要求,供热行业应加速向智能化方向发展.楼宇机组因其成本低、技术先进、节约资源等优势已成为未来发展的必然趋势.文章首先研究了DFMEA(设计失效模式及后果分析)相关理论的国内外现状,然后基于DFMEA可靠性设计技术分析了楼宇机组换热器的结构和功能,再通过DFMEA对楼宇机组换热器进行失效分析、失效后果分析以及风险优先技术计算,最后针对输出结果提出改进方案,改进方案可有效避免失效模式风险的发生,进而提高并保障了产品质量、工作效率和安全性.
Application of DFMEA in Heat Exchangers of 500 kW Building Units
According to the national carbon neutrality development strategy,the heating industry should accelerate its develop-ment towards intelligence.At present,building units have advantages such as low cost,advanced technology,and resource conservation,so building units are the inevitable trend for future development.In this article,the current situation of DFMEA(Design Failure Mode and Effects Analysis)theory both domestically and internationally is studied.Based on the DFMEA reli-ability design technology,the structure and function of building unit heat exchangers are analyzed,and the DFMEA is used to perform failure analysis,failure consequence analysis,and risk priority technology calculation on the heat exchangers of build-ing units.Targeted improvement plans are proposed for the output results,and ultimately,the product quality,work efficien-cy,and safety are improved and guaranteed by avoiding failure mode risks through improvements.

heat exchangerfailure modeDFMEA

于晓洋、白亚茹

展开 >

大连交通大学 机械工程学院,辽宁 大连 116028

换热器 失效模式 DFMEA

2024

机械研究与应用
甘肃省机械科学研究院

机械研究与应用

影响因子:0.267
ISSN:1007-4414
年,卷(期):2024.37(5)