家电科技2024,Issue(z1) :135-138.DOI:10.19784/j.cnki.issn1672-0172.2024.99.028

实验室接地系统的设计与实施方案

Design and implementation of laboratory earthing system

刘园园 袁娣 甄宝华 徐新
家电科技2024,Issue(z1) :135-138.DOI:10.19784/j.cnki.issn1672-0172.2024.99.028
✕

实验室接地系统的设计与实施方案

Design and implementation of laboratory earthing system

刘园园 1袁娣 1甄宝华 1徐新1
扫码查看

作者信息

  • 1. 中家院(北京)检测认证有限公司 北京 100176
  • 折叠

摘要

实验室接地系统是实验室设计的基本要素,有效保障试验人员人身安全和试验数据的准确性.通过对实验室接地系统的相关要求和作用进行阐述,并通过两个实际接地系统案例的分析和比较,最终得出独立接地系统可以减少电路中干扰信号的结论,为实验室接地系统的设计、建设和改造提供建议和技术支撑.

Abstract

The laboratoty earthing system is the basic element of laboratory design,which effectively guarantees the tester safety and the accuracy of data.Elaborate on the requirements and functions of the laboratory earthing system,and provides suggestions and technical support for the design,construction and rebuilding of the laboratory earthing system through the analysis and comparison of two earthing system.Finally,it was concluded that an independent earthing system could reduce the interfering signal in the circuit.

关键词

实验室/接地系统/干扰/方案/比较

Key words

Laboratory/Earthing system/Interference/Scheme/Comparison