Given the characteristics of protective renovation of cultural heritage buildings,the design difficulties in protective renovation of cultural heritage buildings are analyzed by using the Wuhan Theater as an example.The key points in electrical design of protective renovation of cultural heritage buildings and the appropriate solutions are expounded from the aspects including electrical equipment room,power supply and distribution system,lighting system,equipment and pipeline installation,lightning protection & earthing system and automatic fire alarm system,etc.
关键词
文物建筑/保护修缮/设计要点/现场踏勘/变配电所/管线安装/照明系统/防雷接地
Key words
cultural heritage building/protective renovation/key points of design/site survey/power substation and distribution substation/pipeline installation/lighting system/lightning protection& earthing