深入探讨储能设备替代传统柴油发电机的可行性及其潜在的经济和环境效益;通过对某高层办公楼设计案例的分析,评估储能设备在经济性、放置条件、使用寿命等方面的优势和挑战;基于GB 51348-2019《民用建筑电气设计标准》和GB 51048-2014《电化学储能电站设计规范》等相关标准,对储能设备的容量选择、放置条件及与柴油发电机的对比进行详尽分析;结果表明,尽管储能设备在初始投资和维护方面可能存在更高的成本,但其在环保和可持续性方面的优势不容忽视.

Abstract

In this paper,the feasibility of using energy storage equipment to replace traditional diesel generators and the potential economic and environmental benefits are discussed in depth.A case of high-rise office building design is used to evaluate the advantages and challenges of energy storage equipment in economic benefits,placement conditions,and service life.A detailed analysis is carried out by comparing the capacity selection and placement conditions of energy storage equipment with diesel generators according to the Standard for Electrical Design of Civil Buildings(GB 51348-2019)and Design Code for Electrochemical Energy Storage Station(GB 51048-2014).The results show that,although the cost of energy storage equipment may be higher regarding initial investment and maintenance,the advantages of such equipment in environmental protection and sustainability cannot be ignored.

关键词

储能设备/柴油发电机/消防负荷/非消防负荷/备用电源/事故放电时间/蓄电池最大放电电流/蓄电池最大放电功率

Key words

energy storage equipment/diesel generator/fire load/non-fire load/standby power supply/emergency discharge time/maximum discharge current of battery/maximum discharge power of battery

引用本文复制引用

出版年

2024
建筑电气
中国建筑西南设计研究院 中国建筑学会建筑电气分会 全国建筑电气设计技术协作及情报交流网

建筑电气

影响因子:0.56
ISSN:1003-8493
段落导航相关论文