Research on structural system compatibility of super high-rise building
In order to study the influence of super high-rise building shape and building function on structural selection,two super high-rise buildings with a height of about 400m in low intensity area were taken as cases.The basic conditions of building shape,function,component layout and load conditions of the two cases were briefly introduced.At the same time,the main calculation results of the two cases under horizontal load were compared.Finally,the cost of the two cases was compared with the cost of similar high-rise buildings in the same area.The results show that the two cases not only meet the requirements of building use and elevation aesthetics,but also meet the requirements of structural stress and overall stability and safety.At the same time,it has better economy than similar high-rise buildings in China.It shows that the combination of architectural appearance and function is the basis of the rationality of structural layout,and the harmonious combination of the two can achieve comprehensive optimization.