STUDY AND TREATMENT OF THE STAGGERED JOINTS IN THE GROUND WALL NEAR THE SUBWAY FOUNDATION PIT
For the safety of foundation pit construction adjacent subways,staggered joints of underground continuous walls were treated with MJS reinforcement,cast-in-situ bored piles,horizontal diagonal bracings and reverse lining walls,in order to successfully complete earthwork excavation and bottom closure.The actual engineering results show that such measures can improve the staggered joints of underground continuous walls,thus providing a reference for similar issues,in order to reduce risks in foundation pit construction and protect surrounding subway lines and important structures.