首页|某住宅小区多层建筑渗漏原因分析与修复研究

某住宅小区多层建筑渗漏原因分析与修复研究

扫码查看
南京市某住宅小区6幢多层房屋,屋面、外墙和地下室车库连通口渗漏严重.通过现场勘查渗漏情况,分析原因发现渗漏部位主要是屋面、女儿墙墙身及其与屋面交接阴角部位,外墙、地下室变形缝位置,并综合采用"防排截堵"的技术措施进行防水修复设计,最终取得了良好的经济效益和社会效益.
STUDY ON LEAKAGE CAUSE ANALYSIS AND REPAIR OF MULTI-STORY BUILDING IN A RESIDENTIAL DISTRICT
The roof,exterior walls and basement garage connections of six multi-storey buildings in a res-idential complex in Nanjing were badly leaking.Through site investigation of leakage,it is found that the main leakage sites are roof,parapet wall and its connection with the roof corner,external wall,basement deformation joint location,the waterproofing and repairing design is carried out by adopting the technical measures of"Preventing drainage and blocking up",and good economic and social benefits are achieved.

leakage analysisrepairmulti-story roof

唐理、李刚、郭忠怀

展开 >

江苏省建筑科学研究院有限公司,南京 210008

江苏建科土木工程技术有限公司,南京 210008

江苏建科鉴定咨询有限公司,南京 210008

江苏建科工程设计有限公司,南京 210008

南京市江北新区建设和交通工程质量安全监督站,南京 211899

南京坤佳防水防腐保温工程有限公司,南京 210002

展开 >

渗漏原因分析 修复 多层屋面

2024

建筑技术开发
北京市建筑工程研究院

建筑技术开发

影响因子:0.351
ISSN:1001-523X
年,卷(期):2024.51(3)
  • 1