Numerical Simulation Method for Determining the Anti Floating and Anti floating Water Level of Basements in Linjiang Area
Due to the complexity of groundwater seepage,it is difficult to determine the anti floating water level of the basement in the Linjiang area.By using engineering examples and digital simulation methods to establish geological models and seepage fields,the characteristics of groundwater seepage and changes in groundwater level in the site are analyzed.Combined with the engineering geological conditions,hydrogeological conditions,and topography of the site,the anti floating water level of the basement is comprehensively determined,and verified through monitoring data from long-term regional groundwater level monitoring holes and on-site water level monitoring holes.The engineering practice results indicate that the anti floating and anti water level determined by this method is safe and feasible.
groundwaterdigital simulationlong term monitoringanti floating water level