摘要

降低10kV线路故障率是保障电力系统可靠供电的重要任务.本文从设备安装与保护、地勘与施工方案、定期巡检与维护、安全警示标识、防雷措施以及灾害应急预案等方面探讨了降低故障率的措施.通过提高线路设备的抗外力破坏能力,减少人为破坏和自然灾害造成的故障,可以确保线路的稳定供电,保障电力系统的正常运行.这些措施对于提高线路的可靠性和安全性具有重要意义,可为电力行业的发展做出贡献.

Abstract

Reducing the failure rate of 10kV lines is an important task to ensure the reliable power supply of the electrical power system.In this paper,the measures to reduce the failure rate are discussed in the aspects of equipment installation and protection,geological exploration and construction plan,regular inspection and maintenance,safety warning signs,lightning protection measures and disaster emergency plans.By improving the resistance of line equipment against external force damage and reducing the failure caused by man-made damage and natural disasters,the stable power supply of the lines can be ensured and the normal operation of the electrical power system can be guaranteed.These measures are of great significance to improve the reliability and safety of the lines and can contribute to the development of the electrical power industry.

关键词

10kV线/线路故障率/措施探究

Key words

10kV line/line failure rate/measure exploration