目的 提出并验证了一种双层金属丝网传感器(MWMS)测量肿瘤治疗电场(TTFields)的新方法.方法 通过COMSOL建立圆柱模型并进行仿真,验证了双层MWMS的有效性.明胶和NaCl按照一定比例配置来模拟头颅内部组织和用猪肌肉替代肿瘤组织,并设计单层MWMS测量系统验证单层MWMS测量效果.结果 仿真结果表明,双层MWMS在测量精度上明显优于单层MWMS.实际测试结果表明,单层MWMS可以测出模拟头颅内部组织区域的电场强度和猪肌肉所在位置.结论 双层MWMS为TTFields的电场测量提供了更加精确的工具.
Objective To proposed and validated a new method for measuring tumor treating fields(TTFields)using a double-layer metal wire mesh sensor(MWMS).Methods A cylindrical layered model was established by using COMSOL and simulated to verify the effectiveness of the double-layer MWMS.Gelatin and NaCl were configured in a certain ratio to simulate the internal tissues of the skull,and pig muscle was used to replace tumor tissue.A single-layer MWMS measurement system was designed to verify the measurement effect of single-layer MWMS.Results The simulation results showed that the double-layer MWMS had significantly better measurement accuracy than the single-layer MWMS.The actual test results showed that single-layer MWMS could measure the electric field strength in the simulated internal tissue area of the head and the location of pig muscles.Conclusions The double-layer MWMS provides a more accurate instrument for measuring the electric field of TTFields.

tumor treating fieldssingle-layer/double-layer metal wire mesh sensorsingle-layer MWMS electrical field measurement systeminternal tissue of the skullcylindrical model

彭庆恩、曹群生、吕著海、汪洋、邱献新、洪峰、葛秉铧

展开 >

211106 南京,南京航空航天大学电子信息工程学院

南京医科大学附属脑科医院神经外科

复旦大学附属华山医院放疗中心

肿瘤治疗电场 单层/双层金属丝网传感器 单层MWMS电场测量系统 头颅内部组织 圆柱模型

2023年南京航空航天大学研究生研究与实践创新项目

xcxjh20230402

2024

临床神经外科杂志
南京医科大学附属脑科医院

临床神经外科杂志

CSTPCD
影响因子:1.019
ISSN:1672-7770
年,卷(期):2024.21(5)