首页|Q345R 钢板断后伸长率不合格原因分析

Q345R 钢板断后伸长率不合格原因分析

扫码查看
采用光学显微镜、扫描电镜和能谱仪对断后伸长率不合格的 Q345R 钢板的显微组织、断口形貌以及夹杂物进行观察和分析,分析了导致 Q345R 钢板断后伸长率不合格的原因。结果表明:引起 Q345R 钢板断后伸长率不合格的主要原因是严重的带状组织,尤其是较宽的贝氏体硬组织带、魏氏组织等;硫化物夹杂的存在对钢板的断后伸长率有一定的影响,但不是主要原因。
Reasons Analysis on Unqualified Percentage Elongation after Fracture of Q345R Steel Plates
The microstructure,tensile fracture morphology and inclusions were observed and analyzed by optical microscope,scanning electron microscope and energy disperse spectrometer respectively to find out the reasons for the disqualification of percentage elongation after fracture of Q345R steel plates.The results show that the main reason for the unqualified percentage elongation after fracture was the serious banded structure,especially the wide bainite hard microstructure band and the widmanstatten structure.Existing sulfide inclusions had a certain effect on the percentage elongation after fracture of the steel plates,but it was not the main reason.

Q345R steel platepercentage elongation after fracturebanded structurebainitewidmanstatten structureinclusion

汤海芳、王豹、郑翠军、朱启茂、闫巍

展开 >

秦皇岛首秦金属材料有限公司,秦皇岛 066326

Q345R钢板 断后伸长率 带状组织 贝氏体 魏氏组织 夹杂物

2016

理化检验-物理分册
上海材料研究所

理化检验-物理分册

影响因子:0.599
ISSN:1001-4012
年,卷(期):2016.52(4)
  • 12