Improvement in the design of the axial end discharge system for centrifugal chlorine gas compressors
At Jiangsu Sopo New Materials Technology Co.,Ltd.,the discharge valve under the original cylinder body of the centrifugal chlorine gas compressor was a normally closed valve.During the long-term operation of the unit,the gas seal chambers have worn,resulting in that lubricating oil seeped out and entered the nitrogen seal chamber.The leaked dirty lubricating oil was not discharged in a timely manner and leaked into the internal cavity of the unit,affecting the operation of the equipment.The design of the sewage system of the centrifugal chlorine gas compressor was improved,i.e.installing dirty oil discharge and separation tanks at both ends of the compressor.This way not only prevented dirty oil from entering the equipment,but also effectively collected dirty oil,ensuring the stability of the equipment.
chlorine gas compressorshaft end sewage discharge systemsewage valve