Summary of replacement of metal discharge main pipes for ion-exchange membrane electrolysis cells
The significantly corroded anode discharge main of the electrolytic cell was replaced.The manufacturing technical requirements and installation requirements of the replaced discharge main of the electrolytic cell were provided as well as on-site operation status.In response to the problems encountered during operation,improvement measures have been formulated to eliminate safety hazards in the operation of the electrolytic cell,ensuring the long-term safe and stable operation of the device.
electrolytic celldischarge main pipecatholyte dischargeanolyte dischargemetal main pipe