Technical transformation of negative pressure system for hydrochloric acid filling
The negative pressure system used for filling hydrochloric acid to tank trucks was technically modified,and the problem of the original negative pressure system not being able to maintain the required vacuum degree was solved.In the technical modification,a packed tower was used as the absorption equipment.The design calculation and material selection of the packed tower were introduced.