Treatment of scaling in the outlet pipeline of ammonia blowing tower in primary brine refining process
The causes of scaling in the outlet pipeline of the ammonia blowing tower in primary brine refining process were analyzed as well as its impact on the system.The principle,implementation process,and effectiveness of acid washing method for descaling were introduced.
primary brineammonia removal from brinepipingscalingacid washing method