应用ANSYS有限元分析软件,考虑压力载荷和温度载荷对管板整体应力分布的影响,采用顺序耦合法对发夹式循环冷却器的热端管板在 7 种工况下进行有限元应力分析.结果表明:在压力载荷与温度载荷共同作用下,管板最大等效应力为329.9 MPa,位于布管区内换热管与管板连接处.壳程先停工况下管板的最大等效应力值最大值为332.5 MPa,是发夹式循环冷却器管板的最危险工况.在对管板上最大等效应力处进行当量线性化处理,结合分析设计标准进行强度评定,评定结果均合格.
Stress Analysis and Strength Evaluation of Tubesheet of Hairpin Heat Exchanger
Using ANSYS finite element analysis software,considering the influence of pressure load and temperature load on the whole stress distribution of tubesheet,the finite element stress analysis of hot end tubesheet of hairpin circulating cooler was carried out by using sequence coupling method under seven working conditions.The results showed that under the combined action of pressure load and temperature load,the maximum equivalent stress of the tubesheet was 329.9 MPa,which was located at the connection between the heat exchange tube and the tubesheet in the tube distribution area.The maximum equivalent stress value of tubesheet was 332.5 MPa under shell program stop condition,which was the most dangerous condition of tubesheet of hairpin circulating cooler.The maximum equivalent stress on the tubesheet was treated with equivalent linearization,and the strength was evaluated according to the analysis and design standards.

Hairpin heat exchangerTubesheetFinite element methodStress linearization