不同MHP-BIPV/T系统的实验研究
Experimental Study of Different MHP-BIPV/T Systems
柴云娥 1刘孝敏 1杨林艳 1顾金寿 1魏巍 1刘叶瑞1
作者信息
- 1. 甘肃自然能源研究所,甘肃兰州 730050;甘肃省低碳建筑工程研究中心,甘肃兰州 730050
- 折叠
摘要
以3种不同的MHP-BIPV/T系统为研究对象,研究了 2023年1月5日3组系统的光电、光热和综合效率,结果表明:在室外平均温度为0.7 ℃的天气下,透光—吸热蓝膜MHP-BIPV/T系统、透光MHP-BIPV/T系统、满布微热管MHP-BIPV/T系统的平均电效率可达到13%、13.1%、10.6%,平均综合效率可达到43.9%、65.2%、80%,满布微热管的MHP-BIPV/T系统的综合性能好于透光—吸热蓝膜MHP-BIPV/T系统和透光MHP-BIPV/T系统;3种系统的平均温度均在17.9 ℃,可以满足基本供暖需求.
Abstract
The photovoltaic,photothermal and integrated efficiencies of three groups of systems on January 5,2023 were studied with three different MHP-BIPV/T systems,and the results showed that in the weather with an average outdoor temperature of 0.7℃,the transmissive-heat-absorbent blue-film MHP-BIPV/T system,the trans-missive MHP-BIPV/T system,and the microtubule-full MHP-BIPV/T system with an average electric efficiency can reach 13%,13.1%and 10.6%,and the average comprehensive efficiency can reach 43.9%,65.2%and 80%,and the comprehensive performance of MHP-BIPV/T system full of micro heat pipes is better than that of light-transmitting-heat-absorbing blue-film MHP-BIPV/T system and light-transmitting MHP-BIPV/T system;the aver-age temperatures of the three systems are over 17.9℃ and can meet the basic heating demand.
关键词
光电/光热/MHP-BIPV/T/热管/综合效率Key words
photovoltaic/photothermal/MHP-BIPV/T/heat pipe/combined efficiency引用本文复制引用
基金项目
甘肃省青年科技计划项目(22JR11RA217)
甘肃省住房和城乡建设厅科研项目(JK2021-12)
出版年
2024