首页|Schmidt-Boelter热流传感器的改进和性能测评

Schmidt-Boelter热流传感器的改进和性能测评

扫码查看
为满足常规高超声速风洞连续变迎角试验动态热流测量需求,改进了一种小尺寸Schmidt-Boelter热流传感器.以热流标定装置进行了静态校准和动态测试,得到改进后传感器的灵敏度系数为 57.67 µV·m2/kW,响应时间约 26 ms,截止频率 26 Hz,可覆盖 1~130 kW/m2 的热流范围.基于特征响应时间常数,建立了变迎角速度与最大测量误差的定量关系;参照某阶梯变迎角试验测得的热流数据,对该传感器在一定误差范围内能够满足的最大连续变迎角速度进行了评估.
Improvement,performance test and evaluation for Schmidt-Boelter gage
A kind of the small size Schmidt-Boelter gage was improved for measuring dynamic heat flux in the continuous variable attack angle test in the conventional hypersonic wind tunnel.The Schmidt-Boelter gage improved was statically calibrated and dynamically tested by the heat flux calibration devices.The test results show that the sensitivity coefficient is 57.67 µV·m2/kW,the response time is 27 ms,the cut-off frequency is 26 Hz and the gage range coverage is 1-130 kW/m2.Then the quantitative relation between the continuous variable attack angle velocity and the maximum test error was established based on the feature response time constant.And referring to the heat flux measured in the step variable attack angle test,the maximum velocity of the continuous variable attack angle supported by the gage was evaluated within a certain margin of error.

dynamic heat flux measurementSchmidt-Boelter gagecontinuous variable attack angleconventional hypersonic wind tunnel

朱涛、杨凯、朱新新、徐洋、王辉

展开 >

中国空气动力研究与发展中心 超高速空气动力研究所,绵阳 621000

动态热流测量 Schmidt-Boelter传感器 连续变迎角 常规高超声速风洞

2024

实验流体力学
中国空气动力学会

实验流体力学

CSTPCD北大核心
影响因子:0.405
ISSN:1672-9897
年,卷(期):2024.38(6)