Measurement and Analysis of Thermal Environment of Passive Residential Building during Heating Period in Severe Cold Region
The thermal environment parameters of a passive residential building in the severe cold re-gion were tracked and monitored for 6 months,and the variation characteristics of room temperature and rela-tive humidity of 4 typical households in different heat-ing stages were analyzed.The results show that the av-erage room temperature during the heating period rea-ches 28.2 ℃,and the average indoor relative humidity is 33.9%.If the room temperature can be reduced to 20 ℃ during the heating period,the average indoor rel-ative humidity can increase from 33.9%to 55.6%.Appropriate temperature and humidity are not only beneficial for human comfort and health,but also re-ducing room temperature appropriately can help reduce building energy consumption,and achieve energy con-servation and emission reduction.