Research and practice on coupled and coordinated full load denitrification of 350 MW supercritical circulating fluidized bed boiler
Through a comprehensive analysis of the limiting factors for further reducing the concentration of nitrogen oxide emissions in the flue gas of existing circulating fluidized bed units,a combination of denitrification technology and operational control strategies for 350 MW supercritical circulating fluidized bed boiler units at different loads was proposed.After the project was implemented,it met the full load denitrification requirements of the environmental protection department two years in advance,achieving significant social and e-conomic benefits.It has a good demonstration effect in the same type of circulating fluidized bed unit.
circulating fluidized bedcoupled coordinationfull load denitrificationresearch and practice