Analysis of factors affecting stable operation of carbon monoxide sensors
Carbon monoxide gas is not only an important indicator for determining whether a fire has occurred underground in coal mines,but also one of the main toxic and harmful gases in coal mines.It is an important factor leading to poisoning and death of person-nel and resulting in significant casualties and accidents.By simulating the underground environment with a self-made experimental de-vice,the influence of factors such as carbon monoxide gas and underground water vapor on carbon monoxide sensors was analyzed.The research results can provide a basis for effectively preventing data distortion in the collection of carbon monoxide sensors.