Security monitoring system of coal mines is indispensable to ensure the safe and efficient production of colliery. Due to the special and narrow underground field of the coal mine, the electromagnetic interference can cause a series of misstatements and false positives on the monitoring system, which will severely hamper the safe production of coal industry. In this paper, first, the frequency characteristics of the interference source on the power line are extracted when equipment runs normally. Then the finite difference time domain method is introduced to analyze the effects of the electromagnetic interference parameters on the security monitoring signal line. And the interference voltage of the two terminal sides on the single line is taken as evaluating indexes. Finally, the electromagnetic interference parameters are optimized by orthogonal experimental design based on the MATLAB simulation on the normal operation of equipment.

Security monitoring systemFinite difference time domain method (FDTD)Electromagnetic interference (EMI)Orthogonal experimental design

Xiang Liu、Chaoqun Jiao、Aifen Yao

展开 >

School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China

2015