首页|矿用高分子材料液体组分中游离甲醛测量不确定度评定

矿用高分子材料液体组分中游离甲醛测量不确定度评定

扫码查看
对煤矿用反应型高分子材料液体组分中游离甲醛测量进行不确定度评定,可为试验室游离甲醛含量测定结果质量控制及检测报告的合理性提供科学依据.按照现行标准AQ 1116-2020及GB 18583-2008 对装修材料胶黏剂中有害物质限量的规定,采用乙酰丙酮分光光度法测定煤矿用反应型高分子材料液体组分中游离甲醛含量,并对测量结果的不确定度进行评定.矿用反应型高分子材料液体组分中游离甲醛含量在 95%置信概率(k=2)下的测定结果为(0.056 8±0.001 9)g/kg.结果表明,影响测量不确定度的主要因素包括称量样品、样品吸光度测量重复性、标准曲线绘制以及移取和定容溶液过程等引入的相对标准不确定度,而标准曲线绘制、移取和定容溶液过程是引起测量不确定度的主要因素.为了提升试验室测量结果的准确性,关键在于规范玻璃仪器的使用以及准确进行精细化标准溶液吸光度测试.
Evaluation of uncertainty in measurement of free formaldehyde in liquid components of reactive polymer materials used in coal mines
The uncertainty evaluation of free formaldehyde in liquid components of reactive polymer materials used in coal mines can provide scientific basis for the quality control of free formaldehyde content determination results and the rationality of test reports in laboratory.According to the limit of harmful substances in decoration material adhesives based on the current standards of AQ 1116-2020 and GB 18583-2008,the content of free formaldehyde in the liq-uid components of reactive polymer materials used in coal mines was determined by the acetylacetone spectrophotomet-ric method,and the uncertainty of the measurement results was also evaluated.The content of free formaldehyde in the liquid component of reactive polymer materials in coal mines was determined with 95%confidence probability(k=2)as(0.056 8±0.001 9)g/kg.The researches indicate that the main factors affecting measurement uncer-tainty include the relative standard uncertainty introduced by weighing the sample,repeatability of sample absorbance measurement,drawing of standard curves,as well as the processes of pipetting and diluting solution,furthermore,the processes of standard curve drawing and solution pipetting and diluting are the main factors causing measurement uncertainty.In order to improve the accuracy of laboratory measurement results,the key lies in standardizing the use of glass instruments and accurately conducting precision standard solution absorbance tests.

reactive polymer materials for miningfree formaldehydeliquid componentspectrophotometryun-certaintyabsorbance measurementstandard curve

耿乾浩、徐晓云

展开 >

上海煤科检测技术有限公司, 上海 201401

矿用反应型高分子材料 游离甲醛 液体组分 分光光度法 不确定度 吸光度测量 标准曲线

中煤科工集团上海有限公司科研开发资助项目

02060747823J

2024

煤质技术
煤炭科学研究总院

煤质技术

影响因子:0.393
ISSN:1007-7677
年,卷(期):2024.39(1)