农村电气化2024,Issue(3) :4-8.DOI:10.13882/j.cnki.ncdqh.2024.03.002

双碳背景下储能布点对配网线路的降损实践

Practice of Energy Storage Distribution Points in Reducing Loss of Distribution Network Lines under the Dual Carbon Background

张硕 杨坤 宋浩杰
农村电气化2024,Issue(3) :4-8.DOI:10.13882/j.cnki.ncdqh.2024.03.002

双碳背景下储能布点对配网线路的降损实践

Practice of Energy Storage Distribution Points in Reducing Loss of Distribution Network Lines under the Dual Carbon Background

张硕 1杨坤 1宋浩杰1
扫码查看

作者信息

  • 1. 国网安徽省电力有限公司祁门县供电公司,安徽 黄山 245600
  • 折叠

摘要

电池储能设备具有可控化和模块化的特点,可广泛用于配电网系统,通过在台区调整储能设备的接入位置,观察台区线损变化情况,得出结论:储能设备接入光伏侧,电量基本被就地消纳,实现损耗降低;储能设备接入配变侧,光伏给储能充电时供电半径过大造成线损增加.在配电网的合理位置接入储能设备,有降低线损率的实际效果,可以为电网企业带来收益.

Abstract

Battery energy storage equipment has the characteristics of controllability and modularity,and can be widely used in distribution network systems.By adjusting the connection position of energy storage equipment in the substation area,observing the changes in line loss in the substation area,it can be concluded that when the energy storage equipment is connected to the photovoltaic side,power generation is basically absorbed on site,achieving loss reduction;The energy storage equipment is connected to the distribution transformer side,and the power supply radius of photovoltaic charging for energy storage is too large,resulting in increased line loss.Connecting energy storage equipment at a reasonable location in the distribution network has the practical effect of reducing line loss rate and can bring benefits to power grid enterprises.

关键词

储能电池/降损分析/配电网

Key words

energy storage batteries/loss reduction analysis/distribution network

引用本文复制引用

出版年

2024
农村电气化
中国电机工程学会

农村电气化

ISSN:1003-0867
段落导航相关论文