能源工程2024,Vol.44Issue(5) :54-58.DOI:10.16189/j.nygc.2024.05.008

1030MW机组凝结水水质间歇性异常原因分析

Analysis of intermittent abnormal condensate water quality of a 1030MW unit

李自贺 陈龙 谢尉扬
能源工程2024,Vol.44Issue(5) :54-58.DOI:10.16189/j.nygc.2024.05.008

1030MW机组凝结水水质间歇性异常原因分析

Analysis of intermittent abnormal condensate water quality of a 1030MW unit

李自贺 1陈龙 1谢尉扬2
扫码查看

作者信息

  • 1. 浙江浙能中煤舟山煤电有限责任公司,浙江 舟山 316100
  • 2. 浙江浙能电力股份有限公司,浙江 杭州 310007
  • 折叠

摘要

火力发电厂凝结水品质异常会导致整个汽水系统设备的结垢、腐蚀、阻力,影响机组的安全可靠运行.某百万等级机组凝结水水质发生间歇性异常,通过分析,排除了凝汽器循环冷却水泄漏、凝结水泵出口样水污染及分析误差、凝汽器补水水质不合格等可能性,结合现场试验和理论计算,确定凝结水泵筒体焊缝泄漏是凝结水水质发生间歇性异常的根源.

Abstract

The quality of condensate water in thermal power plant affects the fouling,corrosion and flow resistance of the whole steam-water system equipment,and further the safety and reliable operation of the power unit.Intermittent abnormal quality in condensate water occurred in a 1030MW power unit.Through analysis,the probobilities on the leakage of condenser circulating cooling water,the sample and analysis error of water pollution at condensate pump outlet,unqualified water quality of condenser water supply were excluded.Combined with field tests and theoretical calculations,the weld leakage of condensate pump barrel was proved to be the source for the occurrence of intermittent abnormal condensate water quality.

关键词

凝结水水质/异常波动/水泵筒体/焊缝缺陷

Key words

condensate water quality/abnormal fluctuation/pump barrel/defects of welding